Loading…

Open on Polymap

Passatge Jaume Blanchart, De 20, L'Hospitalet de Llobregat

The recorded construction year for Passatge Jaume Blanchart, De 20, 08901 L'Hospitalet de Llobregat is 1980. The building is in Centre, L'Hospitalet de Llobregat. The recorded gross floor area is 425 m². Recorded floor uses: Residential, Parking. These records do not confirm current use.

Cadastral façade of Passatge Jaume Blanchart, De 20, 08901 L'Hospitalet de Llobregat
Loading…

General Info

City
L'Hospitalet de Llobregat
District
Districte I
Neighborhood
Centre
Address
Passatge Jaume Blanchart, De 20, 08901 L'Hospitalet de Llobregat
Postal code
08901
Cadastral code
4796615DF2749F
Construction quality category
3

What to know about this building

  • An energy class cannot be established from the certificates linked in the published Polymap dataset.

    Sources and basis

    The published energy sources do not provide a supported class for this building. This does not establish that no certificate exists.

    Data release: barcelona-seo-reviewed-20261016

Building Info

Year built
Approximately 1980
Aboveground levels
7
Recorded gross floor area
425 m²
Cadastral units
3
Apartments
2
Parking
77 m² · 1 cadastral unit(s)
Elevator
Unknown
Floors 4…6Use not recorded
Floors 1…3Residential
Ground LevelParking

Compared with nearby buildings

Comparison group: residential buildings.

Neighborhood: Centre

Selected comparison group: 1340 of 2166 other buildings in this scope.

Construction year
This building1980
Peer median1963

Older than 21% of peers with a known construction year.

1340 of 1340 peers have this value.
Above-ground levels
This building7
Peer median5

Has more above-ground levels than 62% of peers with a known level count.

1340 of 1340 peers have this value.
Gross floor area
This building425 m²
Peer median499.5 m²

Has a larger recorded gross floor area than 45% of peers with a known area.

1340 of 1340 peers have this value.
How this comparison is calculated

Calculated by Polymap from the same published data release. The selected building is excluded; ties are not counted as older, taller or larger. Recorded use does not confirm current use.

Data release: barcelona-seo-reviewed-20261016

Building standards

1978–1981 · Early Energy Regulation

The first energy-saving requirements began to influence housing.

Noise Insulation estimated

Very low
Airborne noise

Voices, television and music through separating walls and floors

Low
Impact noise

Footsteps, moving furniture and objects falling on the floor above

Very low

The plausible construction-year range crosses an acoustic-regulation boundary. Actual performance may correspond to either period.

  • Built in 1980
  • Plausible year range: 1975–1985
  • Construction-year confidence: medium
  • Above-average cadastral category — shown as context, not used to change the rating
  • Building chronology: consistent
Standard at construction

Before NBE-CA — The building predates Spain’s first general acoustic standard, so separating walls and floors were not designed under a common national sound-insulation framework.

Expected range from Construction Profile chronology and regulation period; actual wall, floor and building-services performance has not been measured.

Thermal Insulation estimated

Low
Winter heat retention

How well the original building envelope is likely to retain indoor heat

Low
Summer heat protection

How well the building is likely to limit summer heat from direct sunlight

Loading…

Likely to lose heat relatively quickly and require more heating than newer buildings.

The plausible construction-year range crosses a thermal-regulation boundary. Actual performance may correspond to either period.

  • Built in 1980
  • Plausible year range: 1975–1985
  • Construction-year confidence: medium
  • Building chronology: consistent
  • Above-average cadastral category — shown as context, not used to change the rating
Standard at construction

Decree 1490/1975 — Spain’s first broad energy-saving rules began limiting heat transmission through the building envelope, but requirements were modest by modern standards.

Summer protection is a comparative building-level estimate. Window size and orientation, external blinds, ventilation, the exact apartment floor and air conditioning are not yet known.

Expected original envelope standard. Current windows, facade and roof insulation, thermal bridges and undocumented works are unknown.

Energy Efficiency

Class
Unknown
Certificates
0

No matched energy certificate is available for this building.

Location

Footprint centered for display; open the map for the surrounding streets.

Coordinates: 41.36302, 2.09923

What is not confirmed

  • Elevator availability is not confirmed.

Missing records do not prove that a feature or certificate does not exist.

Calculation methods

Calculated estimates describe the construction period, not measured performance or the condition of an individual apartment.

Sources and limitations

Overview prepared:

Sources & Updates

These datasets belong to this release. Inclusion does not mean that a record exists for this building.

barcelona-seo-reviewed-20261016